Study record
Muscles and the release in archers: Martin 1990
Electromyographic analysis of bow string release in highly skilled archers
Citation
Martin, P. E., Siler, W. L., & Hoffman, D. (1990). Electromyographic analysis of bow string release in highly skilled archers. Journal of Sports Sciences, 8(3), 215-221. https://doi.org/10.1080/02640419008732147
DOI: 10.1080/02640419008732147
Cite the study
Martin, P. E., Siler, W. L., & Hoffman, D. (1990). Electromyographic analysis of bow string release in highly skilled archers. Journal of Sports Sciences, 8(3), 215-221. https://doi.org/10.1080/02640419008732147
@article{martin1990emgrelease,
author = {Martin, Philip E. and Siler, William L. and Hoffman, Dean},
title = {Electromyographic analysis of bow string release in highly skilled archers},
year = {1990},
journal = {Journal of Sports Sciences},
volume = {8},
number = {3},
pages = {215--221},
doi = {10.1080/02640419008732147}
}
Technical details
- Design
- Cross-sectional study
- Population
- Archers
- Participants
- 15
- Type
- Journal article
- Peer review
- Not stated
- Published in
- Journal of Sports Sciences
What it measured and what it found
Fifteen archers from the United States team, eight men and seven women, mean age 24.7 years, with a mean FITA score for the season of 1,211 out of 1,440 and a best of 1,248, each shot six arrows with surface electromyography on the flexor digitorum superficialis and the extensor digitorum of the string arm. The group included the gold and silver medallists from the 1984 Los Angeles Games.
The principle taught is that the string should be let go by relaxing the flexors, without opening the fingers. The flexor behaves as expected in all fifteen: nearly constant activity over the first 900 milliseconds of the window analysed, then a fall in the hundredth of a second before the string leaves, and a decline that continues afterwards. The extensor splits the group in two. Eight archers show a fall there as well, that is, the release by relaxation of the coaching manuals. The other seven show a brief, sharp peak of extensor activity over the two hundred-millisecond intervals before the string leaves: the fingers open actively.
Neither group shoots better than the other. The mean FITA score for the season was 1,209 for the eight in the first pattern and 1,213 for the seven in the second. Each archer repeated his or her own pattern consistently over the six arrows: the coefficient of variation within a person was 16.2% for the flexor and 14.9% for the extensor, while between people it rose to 52.5% and 51.2%. Another unexpected finding: at full draw all fifteen kept both flexor and extensor active, well above resting levels, whereas the extensor was expected to be nearly silent.
How it was measured
One session per archer, in the university biomechanics laboratory. The recording sites were found by palpating the muscles while the archer simulated the shooting position and contracted maximally; the skin was shaved, lightly abraded and cleaned with alcohol, then 16 mm bipolar silver / silver chloride electrodes were placed about 2 centimetres apart, with inter-electrode resistance checked and the preparation repeated if it exceeded 5 kiloohms. The amplifiers filtered below 1 hertz and above 900, with a 60 hertz notch for mains interference; sampling was at 800 hertz.
Before shooting, each archer performed maximal isometric contractions of the flexors and extensors, sampled for two seconds at the peak, which serve as the reference: all shooting values are expressed as a percentage of that maximum. Then, after a rest and a few practice arrows, activity was recorded over five seconds for six shots, with sampling triggered by hand just after full draw was reached, so that the release fell roughly in the middle of the window.
For synchronisation, an electromechanical device on the bow marked two events: the clicker closing against the handle and, through an inertial switch, the acceleration of the bow as the string left. On average 185 milliseconds passed between the two. The analysis covers two seconds, from one second before the release, split into twenty intervals of a hundred milliseconds; the signal was full-wave rectified and integrated in each interval, and for each archer the mean of the six arrows was computed.
The method explained: How the phases of the shot are timed, Surface EMG in archery: what it measures and how to read it, The instrumented clicker and measuring draw length
Limitations
Six arrows per archer, in a laboratory, and the paper does not say at what distance or on what target face the shooting took place: the quality of the six shots analysed is not recorded, so whether they were good shots is unknown. The comparison between the two patterns uses FITA scores from the current season, gathered elsewhere and in competition, not the arrows measured here: 1,209 against 1,213 are means of eight and seven people, reported with no test at all. With groups that small, a real difference of a few points would not show up anyway.
Surface electromyography on the forearm also picks up activity from neighbouring muscles. The electrodes over the extensor digitorum sit among other extensors, and the study does not discuss this crosstalk: the burst attributed to the extensor digitorum could come in part from adjacent muscles.
Above all, the argument being tested is about the behaviour of the string, and the string was not measured. The coaching argument is that opening the fingers deflects the string sideways and makes the shot less consistent; what is seen here is only muscle activity, with no measure of lateral movement of the string, the nock or the arrow. The study can say that both patterns exist among very strong archers, not that they produce the same string behaviour. The setting is 1990, with the equipment of the time.
What it means for archers
This page matters to anyone who has been told that the release is only a letting go. Among fifteen archers from the United States team, including the two 1984 Olympic medallists, half opened their fingers actively, with a burst of extensor activity two tenths of a second before the string left, and scored the same as the other half. The precept, taken as a general rule, does not describe what the best archers do.
The finding the authors highlight is a different one, and it is worth more: each archer repeated his or her own pattern far more consistently than the fifteen resembled each other. Variability within a person was about a third of the variability between people. What sets a strong archer apart, they suggest, is not which mechanism is used but how faithfully it is reproduced.
One thing the study did not check is worth stating: neither the string nor the arrow was measured, so the question of whether an active opening pushes the string sideways is still open.
In the registry
The claims this study is evidence for, with its position and the current status.
- CorroboratedAbout 150 points on a FITA round separate a club archer from a national-team archer (context)
- ReportedExpert archers repeat the shot with less variability than beginners (for)
- RefutedThe release should be passive: the fingers relax rather than open (against)
- RefutedElite archers share one single correct shooting technique (against)
- CorroboratedBetween one and a half and two tenths of a second pass between the clicker sounding and the arrow leaving (for)
Articles that use it
Research line
Population and discipline
Dossier: how later research took it up
21 studies in the registry cite it, from 1992 to 2025. The most recent are listed below.
- 2025Associations of Scoring Accuracy with Postural Stability and Strength Measures in Archers on a Standard Archery Site
- 2024The effect of 6-week different resistance training on shooting performance among elite archers
- 2024Injuries and Persistent Pain in Elite Adolescent Archery Athletes: A Cross-Sectional Epidemiological Study
- 2023Multi-muscle Synergies of Postural Control in Self- and External-Triggered Force Release During Simulated Archery Shooting
- 2023Effect of exercise devised to reduce arm tremor in the sighting phase of archery
- 2022Twelve-Week Lower Trapezius-Centred Muscular Training Regimen in University Archers
- 2022Performance assessment in archery: a systematic review
- 2020Effects of Dehydration on Archery Performance, Subjective Feelings and Heart Rate during a Competition Simulation
- 2019A machine learning approach of predicting high potential archers by means of physical fitness indicators
- 2018Analysis of Muscular Activity in Archery: A Comparison of Skill Level
- 2016Identification of temporal factors related to shot performance for indoor recurve archery
- 2011A Three-Dimensional Analysis of Finger and Bow String Movements During the Release in Archery
and 9 more studies: listed in the research line From the total on the scorecard to the arrow's coordinates.
Same research line
- 1992Archery Bow Grip Force Distribution: Relationships with Performance and Fatigue
- 2003Activation patterns in forearm muscles during archery shooting
- 2005Psychological Aspects of Archery
- 2005Quantification the relationship between FITA scores and EMG skill indexes in archery
- 2006Archery performance level and repeatability of event-related EMG
- 2009Characteristics of time spent on each phase during archery shooting: A study of the men's and women's individual gold medalists from the World Outdoor Archery Championships
Cite this record
Campagna, M. (2026). Study record: Electromyographic analysis of bow string release in highly skilled archers. In Evidence Registry. matteocampagna.com. Retrieved 16 October 2026, from https://matteocampagna.com/en/evidence/martin-1990-emg-release
@misc{campagna2026_enevidencemartin1990emgrelease,
author = {Campagna, Matteo},
title = {Study record: Electromyographic analysis of bow string release in highly skilled archers},
year = {2026},
howpublished = {Evidence Registry, matteocampagna.com},
url = {https://matteocampagna.com/en/evidence/martin-1990-emg-release},
note = {accessed 2026-10-16}
}
Registry updates by email
At most one email a month, sent only when something has changed: claims that change status, new claims, Lab predictions registered or resolved, new studies and new books.
Sign-ups are handled by Systeme.io, the service that runs the newsletter. Every email has a link to unsubscribe with one click.